Insulin Pump Therapy (CSII – Continuous Subcutaneous Insulin Infusion)

Insulin pump therapy (CSII – Continuous Subcutaneous Insulin Infusion) is the gold standard of insulin treatment, primarily for patients with type 1 diabetes mellitus, and in rare cases, for patients with other types of diabetes as well.

Who can use an insulin pump?

Not every person with type 1 diabetes wants or needs an insulin pump for their therapy.

  • Worldwide, about 9–10 million people live with type 1 diabetes (T1D).
  • Expert sources estimate over 1 million insulin pump users globally (T1 + T2). Since pumps are mainly used by people with T1D, this suggests roughly 8–1.0 million T1D pump users, or about 8–12% of all people with T1D worldwide.

The rate varies greatly by country and healthcare access:

  • United States: about 60–66% of people with T1D use pumps (2017–2021).
  • Sweden (pediatric data): pump use reached ~90% (2013–2022).
  • China: much lower, around 15% depending on the cohort.

Currently, in Germany, around 140,000 people with type 1 diabetes use such a device, which represents about 38% of the roughly 370,000 affected individuals [1]. Even a “classic” insulin pump therapy is expensive: the pump itself costs €3,000–4,000 and is typically used for four years, which corresponds to about €3 per day. Annual costs for consumables such as infusion sets, catheters, etc., amount to another €1,000–2,000, adding roughly €5 per day. Therefore, the daily therapy cost is about €8 higher than for intensified conventional therapy (ICT).

Pump costs and annual infusion set/catheter expenses across Europe, the USA, and India.

October 2025 overview of estimated insulin pump costs and annual infusion set/catheter expenses across Europe, the USA, and India.
(Figures are approximate and vary by model, manufacturer, insurance coverage, and local pricing.)

Region

Pump purchase cost

Annual cost for consumables (infusion sets, catheters, reservoirs, etc.)

Europe

Example (UK): about £2,000–£3,000 (~€2,300–€3,500) per pump. (BreakthroughT1D UK)

European studies estimate around €1,000–€1,400 per year for infusion sets and reservoirs. (Wikipedia – Insulin pump)

USA

Without insurance: typically US$4,500–8,000+ per pump. (ProMed DME)

Consumables: roughly US$1,500–4,000 per year. (ProMed DME) One Medicare-based estimate (including pump, supplies, insulin) was US$3,329/year amortized. (CMS.gov)

India

Typical retail price ₹100,000–₹600,000 (~€1,100–€6,600), depending on model and brand. (HospitalStore.com)

Example pricing: infusion set (pack of 10) ₹3,797, reservoir (pack of 10) ₹1,485. (T1DF India)

Notes & limitations

  • These are out-of-pocket costs unless insurance or public healthcare covers them. In many European countries, the cost is largely reimbursed.
  • Annual supply costs depend on how often infusion sets and catheters are replaced, the brand, and user habits.
  • In India, limited reimbursement means higher personal expenses for most users.
  • The prices listed exclude insulin, CGM/FGM sensors, physician visits, and training costs.
  • Currency fluctuations and local purchasing power can significantly affect real-world costs.

When a CGM (Continuous Glucose Monitoring) system is added to perform sensor-augmented pump therapy (SuP) or to use a hybrid closed-loop / automated insulin delivery (AID) system, additional costs for glucose sensors arise. Depending on the system, these range between €1,700 and €4,200 per year (the wide price range is due to sensor wear time, which varies between 7 and 15 days).
Thus, AID therapy in Germany about €15–20 more per day than ICT.

Approximate costs for continuous glucose monitoring (CGM) sensors in Europe, the USA and Andia. These are rough estimates, since actual out-of-pocket costs vary widely depending on insurance, country reimbursement, brand/model and usage.

 USA

  • Cash-price reports indicate CGM supplies (sensors + transmitter) can cost US$160-500 per month when paying out-of-pocket. (Healthline)
  • One study estimated ~US$15.20/day for a CGM system (≈ US$5,550/year) including sensor + receiver + transmitter in the U.S. context. (PMC)
  • Example: The Eversense 365 CGM system claims “as low as US$199 for a full year” in some insured cases (sensor + transmitter) in the U.S. (Eversense)

Summary for USA: Expect anything from ~US$2,000-6,000/year (or US$160-500/month) before insurance.

 Europe

  • Specific published figures are less clear. However, one pricing guide mentions “~US$260-299 per month” for sensors in a Canadian/Western context (close to European pricing) for one major brand. (endorhealth.com)
  • European brand sites (e.g., FreeStyle Libre) describe products but do not list full retail out-of-pocket pricing publicly. (FreeStyle Libre)

Estimate for Europe: Based on available data, CGM sensors might cost roughly €250-300/month (≈ €3,000-3,600/year) before reimbursement in many Western European countries—but actual costs could be lower or higher depending on country subsidies.

 India

  • One listing for FreeStyle Libre sensor shows price around ₹5,138 for a unit (online retail). (Amazon Indien)
  • Indian press report: People living with T1 diabetes “spend at least Rs 12,000 per month … on CGM sensors” and in some cases “nearly Rs 20,000/month” (~₹240,000/year) when more expensive sensors are used. (The Times of India)

Summary for India: The cost is highly variable. Some data suggest ₹5,000+ per sensor unit, but actual monthly costs for using a CGM may reach ₹10,000-20,000/month (~₹120,000-₹240,000/year) in some cases.

 Important caveats

  • These figures assume out-of-pocket costs (without full insurance/health-system coverage).
  • Many countries/insurance plans reimburse part or all of the CGM cost, which significantly lowers patient costs.
  • Different sensors have different lifetimes (e.g., 7 days, 10 days, 14 days, or even longer), which affects cost per month/year.
  • The quoted Indian figures may include combined costs (sensor + insulin + other supplies) and may not purely reflect the sensor alone.
  • Currency fluctuations and purchasing power differences mean simple conversions may mis-represent “real” burden.

Country-specific pricing examples for continuous glucose monitoring (CGM) sensors in Germany, the UK, India (as available, 2025/10), along with some product listings. Please note: These are retail or indicative costs and may not reflect reimbursed amounts, insurance coverage, or bulk/contract pricing.

 Germany

  • According to a Reddit user quoting German health-insurance coverage: “The sensors are 2.784,60 € … per 12×3-pack … equals ~232,05 € per pack of 3, and ~77,35 € per individual sensor.” (Reddit)
  • A German information site states: CGM systems with alarms (rtCGM/iscCGM) are reimbursable after application if medically necessary. (Diabinfo)
  • Product listings:

Interpretation: In Germany, brush-prices for sensors can be in the range of ~70-100 € each (or more depending on model). Yearly costs for someone using a sensor every ~2 weeks could sum to ~1.500-2.000 € or higher (depending on frequency and model).

United Kingdom

  • A cost comparison table (July 2024) for CGM sensors shows cost per sensor + applicator around £23 to £37.50 for some devices. Annualised cost for 24-36 sensors approx £900-£950/year. (birminghamandsurroundsformulary.nhs.uk)
  • bei der stellen £74.99 for one sensor. (The Care Pharmacy)

Interpretation: In the UK, some sensors are priced quite lower (in the budget ~£23-£40 range) under certain procurement/contracted contexts, but retail/online may show higher prices (~£75). For regular replacement (say every 14 days), annual cost might around £500-£900+ depending on model and usage.

 India

  • Online listing: FreeStyle Libre 3 Plus Sensor or its variant: One listing of FreeStyle Libre sensor shows cost around ₹5,138 for a unit. (Amazon Indien)
  • Media report: Some people with T1 diabetes in India spending “at least Rs 12,000 per month … on CGM sensors” in some cases up to ~Rs 20,000/month. (~₹120,000-₹240,000/year) in some high-cost cases. (Amazon Indien)

Interpretation: In India, pricing is very variable. One sensor item shows ~₹5,000, but in practice recurring costs (especially with imported devices, frequent replacement, no reimbursement) may lead to many tens of thousands of rupees per year.

Summary Table (Estimated)

Country

Approx sensor / unit cost

Annual estimate (device only)

Germany

~70-100 € each

~1.500-2.000 € or higher

UK

~£23-£75 each

~£500-£950+

India

~₹5,000+ each

₹60,000+ to ₹240,000+ or more

Important Caveats

  • These are retail/off-the-shelf price indications, not necessarily what a patient pays after insurance or national reimbursement.
  • Many countries have reimbursement/coverage programs which significantly reduce patient cost (Germany statutory insurance may cover CGM in certain conditions) (Diabinfo)
  • The sensor lifetime (e.g., 10 days, 14 days, or longer) affects how many sensors are needed per year → affects annual cost.
  • Some listings may be for units not fully compatible with local regulatory/insurance environment, or may reflect grey-market or online portals.
  • Conversion between currencies and purchasing power vary; simply comparing numbers may not reflect the “burden” for patients in each country.

The daily therapy costs are higher than for intensified conventional therapy (ICT).

However, the investment pays off: most AID users achieve HbA1c values around 7%, a Time in Range (TIR) of 70% or higher, and only a low risk of severe hypoglycemia [2,3]. This means that diabetic complications become unlikely — at least if AID therapy is started early.

Requirements for coverage by statutory health insurance funds

The following section is only a rough overview of reimbursement eligibility in each region and is subject to change

United States

Regulatory status

  • Insulin infusion pumps are FDA-regulated Class II devices (special controls) under 21 CFR 880.5725. Interoperable “ACE” pumps and other automated insulin delivery (AID) components are also Class II with device-specific special controls. (eCFR)

Who qualifies (coverage/eligibility)

  • Medicare covers pumps for people with insulin-requiring diabetes who demonstrate insulinopenia (e.g., fasting C-peptide ≤110% of the lab’s lower limit of normal, with glucose ≤225 mg/dL; antibody positivity can substitute). Prior authorization and documentation by the treating clinician are required. Private insurers usually mirror these rules. (cms.gov)

Common restrictions

  • Prescription only; device-specific age indications (e.g., some pumps cleared for ≥6 years). Prior diabetes education and regular specialist follow-up are usually expected by payers. (FDA Access Data)

Europe (EU/EEA + UK examples)

Regulatory status

  • Pumps are placed on the market with CE marking under the EU Medical Device Regulation (EU) 2017/745; insulin pumps are generally Class IIb active devices. Market access is EU-level, but reimbursement is national. (Public Health)

Who qualifies (examples of national rules)

  • United Kingdom (NICE TA151): Offer a pump to people ≥12 years with disabling hypoglycaemia or HbA1c ≥8.5% (69 mmol/mol) despite optimized multiple daily injections (MDI); <12 years when MDI is impractical (with a later MDI trial advised). Hybrid closed-loop access is expanding but still phased and criteria-based. (NICE)
  • France: Pumps (and AID systems) are reimbursed when listed on the LPPR after HAS/CNEDiMTS assessment; listings can include device + consumables + training/follow-up packages with specified tariffs. (G_NIUS)
  • Germany: Statutory insurers reimburse CSII when clinically indicated and prescribed by specialists; (recent decisions also addressed AID). Specific coverage is governed by the federal benefit framework (G-BA) and sickness funds. (PMC)

Common restrictions across Europe

  • Always prescription/specialist-led care.
  • Typical criteria: recurrent/severe hypoglycaemia, hypoglycaemia unawareness, poor control despite optimized MDI and education, or practical barriers to MDI (particularly in young children). Country-to-country thresholds and paperwork differ. (NICE)

India

Regulatory status

  • Insulin (ambulatory) infusion pumps are regulated as medical devices under India’s Medical Device Rules, 2017 by the CDSCO; infusion pumps fall under notified classifications (commonly cited as Class C) and require licensing. (cdsco.gov.in)

Who qualifies (coverage/eligibility)

  • No uniform national reimbursement. Access is primarily out-of-pocket or via select private insurance policies that may cover pumps/consumables; benefits and exclusions vary widely. (PMC)
  • Public schemes: The federal AB-PMJAY (Ayushman Bharat) provides cashless hospitalization cover for eligible low-income families but does not consistently cover personal insulin pumps; some state programs (e.g., Kerala, Himachal Pradesh) have announced free pumps for children or eligible residents via state health missions and program budgets. Expect local criteria, residency proof, and specialist approval. (web.umang.gov.in)

Common restrictions

  • Specialist prescription and training. Coverage—if available—often limited to children with type 1 diabetes under specific state schemes; otherwise self-pay with periodic supplies. (nhm.hp.gov.in)

In brief:

How are pumps regulated?

  • USA: FDA Class II devices with special controls (including interoperable ACE pumps/AID components). (eCFR)
  • Europe: CE-marked under EU MDR 2017/745 (typically Class IIb); reimbursement handled nationally. (Public Health)
  • India: Regulated by CDSCO under Medical Device Rules, 2017 (infusion pumps classified and licensed). (cdsco.gov.in)

Are there restrictions?
Yes—everywhere. Pumps are prescription devices, usually require specialist initiation and training, and payer criteria (e.g., documented hypoglycaemia, failure of optimized MDI, or specific lab evidence in the US). Device-specific age indications also apply. (NICE)

Who is entitled to a pump?

  • USA: Those meeting medical necessity and Medicare/private insurer criteria (notably C-peptide/autoantibody thresholds for Medicare). (cms.gov)
  • Europe (example rules): People with type 1 diabetes who cannot achieve targets on MDI or have disabling hypoglycaemia (e.g., NICE TA151 in the UK); similar specialist-driven criteria exist in many EU countries, but details (and generosity) vary by country. (NICE)
  • India: No blanket entitlement nationally; eligibility depends on state schemes (where present) or individual insurance terms; otherwise, access is self-funded. (nhm.hp.gov.in)
  • Same medical idea, very different pathways: In the US and many European systems, clear clinical criteria + insurer rules determine access; in India, regulatory approval exists, but coverage is patchy, with some state-level programs for children and otherwise out-of-pocket or private policies. (Med Tech Reimbursement Consulting)

It can also be observed that there is greater openness to prescribing insulin pumps for children and adolescents with diabetes. Because of the effectiveness of CSII combined with an AID system (improving metabolic control and reducing acute complications), international guidelines recommend AID as a first-line therapy for children and adolescents with type 1 diabetes [6]. In Germany, about 70–80% of these young people with diabetes use such a system.

For AID systems, approval is in some cases somewhat easier due to the typically excellent glucose control they achieve.

Main indications for prescribing an insulin pump

  • Dawn phenomenon: This refers to an increase in blood glucose levels in the early morning hours. Fasting glucose is consistently high due to the release of counter-regulatory hormones (cortisol, catecholamines, growth hormone, and glucagon). In ICT, the dawn phenomenon cannot be compensated by adjusting basal insulin. Long-acting analog insulins can cover the “insulin gap” that may occur with NPH insulin in the morning, but not the increased insulin demand caused by these hormones. With an insulin pump, the basal insulin delivery can be increased in the morning, as only rapid-acting insulin is used for basal needs. Adjusting the basal rate accordingly improves fasting glucose levels and overall control.
  • Brittle diabetes: Patients with unstable metabolic control and large blood glucose fluctuations.
  • Physically active patients and athletes: The basal rate can be temporarily reduced to prevent hypoglycemia and reduce the need for additional carbohydrate intake (temporary basal rate adjustment).
  • Frequent hypoglycemia
  • High insulin sensitivity and low daily insulin requirement
  • Patients with irregular daily schedules, such as pilots or shift workers
  • Women with type 1 diabetes during pregnancy
  • Children with type 1 diabetes
  • Here’s a fluent and accurate English translation of your text:
  •  
  • With AID: Better Metabolic Control, Fewer Complications
  • These indications apply to all forms of insulin pump therapy. In the case of AID systems (Automated Insulin Delivery), however, a certain expansion can be seen: glucose control is usually excellent, with HbA1c values ≤ 7%, time in range (70–180 mg/dl / 3.9–10.0 mmol/l) ≥ 70%, and no severe acute complications such as severe hypoglycemia or diabetic ketoacidosis [7, 8]. This applies not only to adults but also to children and adolescents [6].
  • Data from real-world use—so-called real-world analyses involving large patient groups—confirm these findings [5]. Costly diabetic complications are unlikely if this form of therapy is introduced early. Considering that treating such complications is expensive, the use of an AID system is actually cost-effective.
  • Another crucial point is that such good glucose control can be achieved without extreme effort on the part of those affected. Of course, patients must still pay close attention to many aspects of their therapy management, but automation greatly reduces their burden—much like the automatic braking system in a car. This technology even offers an opportunity for use in patients with cognitive impairments [7].
  • In essence, insulin pump therapy (CSII) with an AID system provides people with type 1 diabetes not only with excellent metabolic control (glycemia) but also with a significant improvement in quality of life despite their condition.
  • The majority of diabetologists with experience using AID systems believe that, in principle, every person with type 1 diabetes should have access to CSII with AID, provided they wish to use it and are able to handle it appropriately.
  •  
  • What Are Insulin Pumps and How Does the Treatment Work?
  • Principle of Insulin Pump Therapy
  • The therapeutic principle of insulin pump therapy corresponds to that of intensified conventional therapy (ICT). All the rules of basal–bolus therapy still apply. However, multiple daily injections are no longer necessary. Instead, a small cannula from an infusion set is placed subcutaneously and is usually changed every 2–3 days (currently, the “Extended Infusion Set” from Medtronic is an exception, requiring a change only about every 7 days).
  • The insulin pump contains only rapid-acting insulin. The superiority of insulin analogues over regular human insulin has been demonstrated for pump therapy. A major advantage is that rapid-acting insulin is absorbed uniformly in the subcutaneous tissue, with a variability of only about 3% [8], in contrast to the 15–40% absorption variability seen with delayed-action (basal) insulins used in ICT.
  • Continuous insulin delivery—the basal rate—covers the body’s basic insulin requirement. In CSII and sensor-augmented pump therapy (SuP), the programmed basal rate is delivered by the pump, having been previously determined under conditions that resemble real life as closely as possible. To enable better personalization, multiple basal rate profiles can be programmed and selected as needed (e.g., for sports, shift work, etc.).
  • In AID therapy, the chosen basal rate is either automatically adjusted according to measured glucose levels or continuously set based on real-time glucose data. In all forms of CSII, meal insulin is administered as a bolus at the press of a button. The bolus does not have to be delivered all at once—various bolus types can be selected, such as a dual or extended bolus for high-fat meals, in which two-thirds of the insulin is delivered immediately and the remainder after a programmable delay. When insulin requirements are lower, the basal insulin can also be temporarily reduced.

• Advantages of “Classic” Insulin Pump Therapy Over ICT: What Do Studies Show?

  • There are numerous advantages of insulin pump therapy (CSII) compared with intensified conventional therapy (ICT). One aspect concerns metabolic control. In addition to improved glucose management—reflected in lower HbA1c levels—hypoglycemia occurs less frequently, particularly severe hypoglycemia. Glucose variability is also significantly reduced.
  • The literature contains more than 1,800 studies documenting these improvements [9]. One example of CSII’s effectiveness is shown in Figure T1D 6, which illustrates the transition of patients with type 1 diabetes and frequent hypoglycemia. Initially, therapy was optimized from conventional insulin (regular/NPH) to ICT using rapid-acting analogue insulin lispro and long-acting analogue insulin glargine—without improvement. Only after switching to CSII with rapid-acting insulin analogues did HbA1c decrease by 6% [10].

 

Fig. T1D 6

Change in HbA1c after switching patients with type 1 diabetes from ICT with regular/NPH insulin to ICT with a rapid-acting insulin analogue/glargine, and after a second switch to CSII (left). On the right, the change in HbA1c is shown in relation to the initial HbA1c value. [10]

This individual example is confirmed by meta-analyses.
An analysis of 22 randomized controlled trials comparing CSII with ICT demonstrated that, on average, CSII improves HbA1c by 0.55% [14].

In another meta-analysis, the results of CSII therapy in patients with type 1 diabetes were examined with respect to the frequency of severe hypoglycemia [15]. Again, 22 studies (10 of them involving children and adolescents) met the strict criteria regarding study duration, patient numbers, etc. The analysis showed that all studies reported a significant reduction in the number of severe hypoglycemic events. Overall, the rate of severe hypoglycemia decreased by a factor of 4.19—that is, by more than three quarters to 23.9%. At the same time, HbA1c improved by an average of 0.61%.

Compared with ICT, CSII reduces the risk of developing cardiovascular disease and lowers mortality [16]. This was shown in an analysis of the Swedish National Diabetes Register, which includes data on about 95% of all people with type 1 diabetes in Sweden.
When using CSII, the event rate per 1,000 patient-years was lower compared with ICT (ICT = 1.0):

  • Coronary heart disease: −18%
  • Vascular diseases (stroke and myocardial infarction): −11%
  • Major coronary heart disease: −44%
  • Non-coronary-related mortality: −18%
  • Overall mortality: −29%

In addition to these significant outcomes, CSII improves the quality of life of people with diabetes. It allows for a more flexible daily routine, much less restricted by insulin therapy. This leads to greater resilience and performance. Irregular professional duties—such as those of business travelers or physicians—can be managed more easily, as can various leisure activities [17].

The Basal Rate in Insulin Pump Therapy – Without AID or SuP

The basal rate, i.e., the distribution of insulin delivery over 24 hours, is often not constant but follows a circadian rhythm.
In the early morning hours, insulin requirements are at their highest due to increased insulin resistance, then remain constant throughout the day, and slightly rise again in the evening.
The distribution roughly corresponds to the basal rate pattern shown below.

The circadian pattern of insulin requirements changes over a person’s lifetime. In long-standing diabetes, the circadian distribution gradually approaches a more constant insulin demand over the full 24-hour period.

In general, less insulin is required under CSII than under previous ICT using basal (intermediate-acting) insulin. This also applies to the basal rate, i.e. the insulin needed independently of food intake.
The determination of the basal rate depends largely on the glycemic control achieved during ICT. If glycemic control was satisfactory, with only a few hypoglycemic episodes, the basal rate is reduced to about 85% of the previous total.
If, on the other hand, hypoglycemia occurred frequently, a reduction of about 30% is recommended.
Thus, it is generally appropriate to initially reduce the basal insulin dose by around 30% compared to ICT.

Step-by-step to CSI using an example (MDI/ICT TDD = 40 U/day with 20 U glargine).

Confirm readiness & choose the system

    • Make sure the person can carb-count, dose safely, and troubleshoot; review DKA prevention and ketone checks.
    • Pick the pump (often an AID/hybrid closed-loop) and infusion set; review training and follow-up. (Diabetes Journals)
  1. Collect recent data & set initial targets
    • Review glucose logs/CGM and current doses.
    • Typical adult pump targets are around 100–120 mg/dL (device-dependent). (Diabetes Teaching Center)
  2. Choose a starting “pump TDD” (often slightly lower than on injections)
    Common U.S. protocols reduce injection TDD by ~25% at pump start to lower early hypoglycemia risk:
    • Pump TDD = 0.75 × injection TDD → 0.75 × 40 U = 30 U/day.
      Some centers also cross-check with weight formulas. (Tandem Diabetes)
  3. Split pump TDD into basal vs bolus
    • Start with ~50% basal / 50% bolus (ADA/teaching materials and many clinic order sets).
    • With Pump TDD = 30 U → Daily basal ≈ 15 U and daily bolus pool ≈ 15 U. (Diabetes Journals)
  4. Convert daily basal to an average hourly rate
    • 15 U ÷ 24 h = 0.625 U/h → program ~0.60–0.65 U/h as the average, then shape the day (see Step 6).
    • Alternative U.S. method (also used): divide prior glargine by 24 → 20 U ÷ 24 ≈ 0.83 U/h as an initial manual basal, then adjust. (If residual long-acting is still on board the first day, reduce temporarily—see Step 7.) (Tandem Diabetes)
  5. Shape the basal profile across the day
    • Begin with 1–4 time blocks (e.g., small dip overnight, rise 3–7 AM for dawn phenomenon, slight evening bump).
    • Fine-tune based on fasting blocks (“basal testing”) aiming for flat glucose (roughly within ~30 mg/dL over a test block). (Mein Arzt Online)
  6. Handle the last glargine dose (overlap on day 1)
    Two common, guideline-concordant approaches in the U.S.:
    • Wait-out method: Start full programmed basal when glargine is essentially gone (~24 h after the last dose).
    • Overlap-safe method: Start the pump sooner but reduce/zero the basal for 6–24 h (e.g., temp basal 0–70%) to account for residual glargine, then return to the programmed basal when the long-acting insulin has worn off. Manufacturer order sets explicitly recommend a temporary basal of 0% until the last long-acting dose is inactive; ADA pump-start texts note 30–50% basal reduction for 6–24 h when residual basal is present. (Tandem Diabetes)
  7. Set initial bolus math (rules of thumb, then personalize)
    • Insulin-to-carb ratio (ICR): many U.S. templates start with 450–500/TDD. With Pump TDD = 30 U → ICR ≈ 1:15 g (450/30) to 1:17 g (500/30).
    • Correction factor (ISF): 1700–1800/TDD. With 30 U → about 1 U drops ~55–60 mg/dL. (Devices vary; order sets often use 1700/450.) (Tandem Diabetes)
  8. Decide AID vs. manual start
    • If using an AID system, many clinicians start in manual or limited-automation for the first day (depending on device policy), then enable full automation once baseline settings and sensor calibration are stable. Algorithms will then adapt beyond the manual basal shape. (Diabetes Journals)
  9. Educate, monitor closely, and adjust
  • Do structured basal tests on separate days: midnight–breakfast, late-morning–afternoon, and evening blocks (no meal for 4–6 h, check CGM/fingersticks every 1–2 h). Adjust the relevant time block by ~10–20% as needed.
  • Reinforce infusion-set rotation, sick-day rules/ketones, and rapid troubleshooting for unexplained highs (check site, ketones, correction + set change). (Mein Arzt Online)

Wait-out method: Start full programmed basal when glargine is essentially gone (~24 h after the last dose).

Overlap-safe method: Start the pump sooner but reduce/zero the basal for 6–24 h (e.g., temp basal 0–70%) to account for residual glargine, then return to the programmed basal when the long-acting insulin has worn off. Manufacturer order sets explicitly recommend a temporary basal of 0% until the last long-acting dose is inactive; ADA pump-start texts note 30–50% basal reduction for 6–24 h when residual basal is present.

  1. A) “Conservative pump-start” method (very common in U.S. clinics)
  • Pump TDD = 0.75 × 40 U = 30 U
  • Basal ≈ 50% → 15 U/day → ~0.60–0.65 U/h average
  • Shape with a small pre-dawn rise, then adjust via basal testing. (Tandem Diabetes)
  1. B) “Glargine ÷ 24” method (also taught in ADA materials)
  • Hourly basal = 20 U ÷ 24 h ≈ 0.83 U/h as an initial manual basal
  • Day 1 safety: because yesterday’s glargine may still be active, use a temp basal reduction (e.g., 0–70%) for 6–24 h before running the full 0.83 U/h. Then move to basal testing and refine. (Diabetes Journals)

both methods are acceptable in the U.S.

  • National guidance describes the principles (basal ≈ 30–50% of TDD; verify with basal testing) rather than a single fixed “graph.” Clinics therefore use structured calculators/order sets (like the one above) to operationalize a safe start and then individualize quickly with CGM data. (Diabetes Journals)

 Patient scenario

  • Type 1 diabetes, previously on MDI (ICT)
  • Total daily dose (TDD) = 40 U
  • Glargine (basal) = 20 U
  • Goal basal ≈ 50 % of TDD

Method A – “Conservative pump-start” approach

(Used by many U.S. centers to reduce early hypoglycemia risk)

Time block

Relative adjustment

Rate (U/h)

Notes

00:00–03:00

90 % of avg

0.55

prevent nocturnal lows

03:00–07:00

120 % of avg

0.70

dawn phenomenon

07:00–12:00

90 % of avg

0.55

high morning sensitivity

12:00–18:00

100 % of avg

0.60

baseline

18:00–24:00

110 % of avg

0.65

evening rise

Mean

—

≈ 0.61 U/h → ≈ 15 U/day

 

Start in manual mode (not full AID) for 24 h.
 Perform fasting-block basal tests over the next week and adjust each segment ±10–20 %.

Method B – “Glargine ÷ 24” approach

(Often used if the clinician wants to match the prior basal exposure)

Time block

Relative adjustment

Rate (U/h)

Notes

00:00–03:00

90 % of avg

0.75

prevent nocturnal lows

03:00–07:00

120 % of avg

1.00

dawn rise

07:00–12:00

90 % of avg

0.75

high sensitivity

12:00–18:00

100 % of avg

0.83

baseline

18:00–24:00

110 % of avg

0.90

evening tendency to rise

Mean

—

≈ 0.83 U/h → ≈ 20 U/day

matches prior glargine

 Because residual glargine may still be active on day 1, most U.S. clinics start this profile at 50–70 % temp basal for 6–24 h, then return to full rates once glargine has worn off.

 After pump start

  • Check glucose/CGM every 2–3 h for the first 24 h.
  • Perform structured basal tests (fasting 6-h windows) on non-exercise days.
  • Adjust each segment so glucose stays roughly flat (±30 mg/dL).
  • Re-evaluate within 3–7 days with diabetes educator or endocrinologist.

The Methods often fit quite well and can be fine-tuned using basal rate tests. However, basal rate testing is now only rarely necessary, since insulin pumps are mostly used together with CGM systems. This combination makes it easy to adjust the basal rate, and hypoglycemia—especially at night—can be detected early.

With the large number of daily glucose profiles available, it is usually possible to determine whether an issue is due to an incorrect basal rate or an inadequate bolus dose. Therefore, skipping meals to test the basal rate (the “meal omission test”) is now often unnecessary.
However, in some cases, this approach is still useful for precisely determining the correct basal rate.

The Basal Rate in Insulin Pump Therapy – With AID or SuP

In an AID system, the glucose sensor controls the basal insulin delivery of the pump. The algorithm automatically adjusts the initially programmed basal rate to the patient’s actual needs (as with the Tandem t:slim X2 with Control-IQ) or determines it dynamically at short intervals (e.g., every five minutes with Medtronic MiniMed insulin pumps).

The Temporary Basal Rate

In CSII or sensor-augmented pump therapy (SuP), the basal rate can be temporarily increased or decreased as needed. This allows for adjustments to changes in insulin requirements—for example, a reduction during physical activity or an increase during acute illness.

In AID systems, these adjustments occur automatically via CGM measurements and the pump’s insulin delivery algorithm.

In general, the basal rate can be raised or lowered to match the individual’s insulin needs. Thus, changes in insulin requirements due to exercise or illness can be managed dynamically.
In closed-loop systems, the basal rate is automatically adapted based on continuous glucose monitoring.

The Bolus in Insulin Pump Therapy – Without AID

An insulin pump also offers the advantage of variable bolus delivery. The bolus can be administered as a standard bolus, a dual bolus, or an extended (square-wave) bolus.

For slowly absorbed carbohydrates, such as those in fat-rich meals, a delayed bolus can be used—where part of the bolus insulin is delivered immediately and the remainder over a defined period, e.g. two to three hours.

Modern insulin pumps also include a bolus calculator.
Using predefined therapy settings, the calculator suggests an insulin bolus based on the measured blood glucose level and intended carbohydrate intake.
It also takes into account the duration of action of a previous bolus, helping to prevent

The Bolus in Insulin Pump Therapy – With AID

In a modern AID system, the insulin pump is informed only about the carbohydrate amount, or the user simply indicates the type or size of the meal (e.g., small, medium, large; breakfast, lunch, dinner).
These parameters must be defined before the first use of the AID system.

The AID algorithm then calculates the insulin bolus and compensates for fluctuations in insulin requirements by adjusting the basal insulin delivery accordingly.

For most CGM systems, routine fingerstick calibration is no longer necessary, although it can still be performed (except with the FreeStyle Libre system, which does not allow calibration).
Occasional blood glucose measurements, however, are still recommended to verify the accuracy of the system.

Fig. T1D 7:

Insulin action profile during insulin pump therapy.
Only rapid-acting insulin is infused: the individually programmed basal rate covers the insulin requirement independent of food intake, while boluses are delivered at mealtimes or to correct elevated glucose levels.
(Blue dashed lines: insulin levels in people without diabetes.)

 

Communicating with the Computer

All insulin pumps are equipped with an intelligent data management system that, via appropriate interfaces, allows therapy data and basal rate settings to be read and analyzed on an external computer.
There are also mobile applications (apps) available for use on smartphones.

References

[1] Pankowska E et al.: Three kind of mealtime insulin administration and metabolic control in diabetic children on insulin pumps. Diabetologia 2008; 51 (Suppl. 1), S381.
[2] Pańkowska E, Błazik M, Groele L. Does the fat-protein meal increase postprandial glucose level in type 1 diabetes patients on insulin pump: the conclusion of a randomized study. Diabetes Technol Ther. 2012 Jan;14(1):16-22.
[3] Sherr JL, Schoelwer M, Dos Santos TJ, et.al.. ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery. Pediatr Diabetes. 2022 Dec;23(8):1406-1431. doi: 10.1111/pedi.13421. Epub 2022 Dec 5. PMID: 36468192.
[4] Castañeda J, Arrieta A, van den Heuvel T, et.al. Time in Tight Glucose Range in Type 1 Diabetes: Predictive Factors and Achievable Targets in Real-World Users of the MiniMed 780G System. Diabetes Care. 2024 May 1;47(5):790-797.
[5] Silva JD, Lepore G, Battelino T, et.al.. Real-World Performance of the MiniMed™ 780G System: First Report of Outcomes from 4120 Users. Diabetes Technol Ther. 2022;24(2):113-119.
[6] von dem Berge T, Remus K, Biester S, et.al. In-home use of a hybrid closed loop achieves time-in-range targets in preschoolers and school children: Results from a randomized, controlled, crossover trial. Diabetes Obes Metab. 2022 Jul;24(7):1319-1327.
[7] Petry F. AID-System sorgt für überraschende Wende im Diabetesmanagement. In|Fo|Diabetologie 2024;18 (6):6-9.
[8] Heise T, Nosek L, Rønn BB, et.al. Lower within-subject variability of insulin detemir in comparison to NPH insulin and insulin glargine in people with type 1 diabetes. Diabetes. 2004;53(6):1614-1620.
[9] Datenbank Pubmed, Stichwort “diabetes csii”. Letzter Aufruf: 02.06.2025.
[1013] Pickup JC, Kidd J, Burmiston D et al. Effectiveness of continuous subcutaneous insulin infusion in hypoglycaemia-prone type 1 diabetes. Practical Diabetes International 2005; 22: 10 – 14.
[14] Jeitler K, Horvath K, Berghold A et al. Continuous subcutaneous insulin infusion versus multiple daily insulin injections in patients with diabetes mellitus: systematic review and meta-analysis. Diabetologia 2008; 51: 941-951.
[15] Pickup J, Sutten AJ Severe hypoglycaemia and glycaemic control in Type 1 diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion. Diabetic Medicine 2008; 25: 765 – 774.
[16] Steineck I, Cederholm J, Eliasson B, et.al; Swedish National Diabetes Register. Insulin pump therapy, multiple daily injections, and cardiovascular mortality in 18,168 people with type 1 diabetes: observational study. BMJ. 2015 Jun 22;350:h3234.
[17] Liebl A, Krinelke L Long-term results of insulin pump therapy (CSII) in adolescents and adults with type 1 diabetes mellitus in Germany. Diabetologia Polska 2003; 10: 179-185.